COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ref. DTU 100042
Is.Rev. 5.17
Date: Dec. 03, 2021Sept.
30, 2021
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
MSP MODULE
CONNECTOR
LABEL
ELECTRICAL CHARACTERISTICS
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to –60 dBm,
Coherent IF level :
significant from 0 dBm to –100 dBm)
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to –60 dBm,
Coherent IF level :
significant from 0 dBm to –100 dBm)
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input