Page 4
CONNECTOR
TYPE
CONNECTOR
PANEL
LABEL
CABLE
SLEEVE
LABEL
MSP MODULE
CONNECTOR
LABEL
SIGNAL
ELECTRICAL CHARACTERISTICS
TEST POINTS
BNC Female
SET #1
Note 2
I/O NUM board
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
See section 2.3.4.2
BNC Female
SET #2
Note 2
I/O NUM board
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
See section 2.3.4.2
BNC Female
DA-15 Female
SET #3
Note 2
I/O NUM board
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
See section 2.3.4.2
BNC Female
DA-15 Female
SET #4
Note 2
I/O NUM board
Data I, Data Q, Clock IN
Data I, Data Q, Clock OUT
See section 2.3.4.2
BNC Female
VIDEO 1
VIDEO OUT 1
Note 3
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50
BNC Female
VIDEO 2
VIDEO OUT 2
Note 3
Uplink & downlink video test signals
(see section 2.3.4.1for assignment to internal
signals)
DC to 25 MHz (-3 dB attenuation)
2Vpp (adjustable, see note 4)
50
BNC Female
AGC OUT 1
AGC OUT 1
Note 3
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to 60 dBm,
Coherent IF level :
significant from 0 dBm to 100 dBm)
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input
BNC Female
AGC OUT 2
AGC OUT 2
Note 3
AGC voltage Output 1
Non coherent AGC :
significant from -20 dBm to 60 dBm,
Coherent IF level :
significant from 0 dBm to 100 dBm)
0 to 10 V, 10 dB/V
+ 2 V = -20 dBm,
+10 V = -100 dBm
Requires high impedance input