167
Standard/Left-Hand Type Opposite/Right-Hand Type
(1) Feed direction
(1) Feed direction
The setting range varies depending on the print resolution of the product.
The setting range is as follows:
Resolution S84NX S86NX
203 dpi
(1 dot = 0.125 mm
(0.0049"))
-30 to 0 to 30 dots -30 to 0 to 30 dots
305 dpi
(1 dot = 0.083 mm
(0.0033"))
-45 to 0 to 45 dots -45 to 0 to 45 dots
609 dpi
(1 dot = 0.042 mm
(0.0017"))
-90 to 0 to 90 dots -
You can change the units to dots, " (inches), or mm in the [System] > [Regional] >
[Unit] menu.
The changes to this setting are linked and are changed with each of the test print
settings in the [Tools] > [Test Print] menu.
[Pitch Offset]
Pitch Offset adjusts the offset position and the pitch position at the same time.
Set the value '+' to move the offset and pitch positions in the direction opposite to the feed direction
and '-' to move in the feed direction.