Appendix 1 Parameter table
Appendix 192
Short circuit to ground protection
function when start
XX1:Detect leakage current of ground when
inverter starts
0X1:Detect leakage current of ground only for
the first startup
1X1:Detect leakage current of ground for every
startup.
GF detection level when
operating
Total inverter operation time
(minutes)
Total inverter operation time
(days)
Total inverter power on time
(minutes)
Total inverter power on time
(days)
Choose 0~12 recorded alarm
Alarm record code display
Alarm record message query
Choose 0~10 recorded alarm
Alarm record message display
XXX0:Invalid(the fire mode is forbidden(normal
mode))
XXX1:Forward operation(the inverter runs
forward in fire mode)
XXX2:Reverse operation( the inverter runs
reversely in fire mode)
0XXX:Manually exit fire mode 1 ( if the start fire
mode terminal is OFF, the inverter need reset
manually and back to normal mode)
1XXX:Exit fire mode automatically (if the start fire
mode terminal is OFF, the inverter goes to
normal mode automatically)
2XXX:Manually exit fire mode 2(if the start fire
mode terminal is OFF, the inverter keeps
running, need reset manually and back to normal
mode)
Frequency setting in fire mode
Accumulated times in fire mode
Communication protocol
selection
Inverter communication station
number