System parameter group 00
PARAMETER DESCRIPTION 48
Group
Parameter
Number
Name
Setting Range
Default
Page
00-12
P.31
Soft-PWM carrier
function selection
0: Off
0
57
1: When 00-11(P.72)<5,Soft-PWM is on(only apply to V/F
control)
2When 00-11(P.72)9, if the IGBT temperature is higher
than 60°c, carrier frequency will decrease automatically,
when temperature go back to under 4c, carrier frequency
go back to 00-11(P.72) value
00-13
P.71
Idling brake / DC
brake
0: Idling brake
1
58
1: DC brake
00-14
P.75
Stop function
selection
0: Press STOP button and inverter stop running in PU and H2
mode
1
58
1: Press STOP button and inverter stop running in all mode.
00-15
P.78
Prevent
forward/reverse
rotation selection
0: Forward/reverse rotation are both permitted.
0
59
1: Prevent reverse rotation (Giving reverse signal decelerates
and stops the motor).
2: Prevent forward rotation (Giving forward signal decelerates
and stops the motor).
00-16
P.79
Operation mode
selection
0: “PU mode”, “external mode” and “Jog mode” are
interchangeable.
0
59
1: “PU mode” and “JOG mode” are interchangeable.
2: “External mode” only
3: “Communication mode” only
4: “Combined mode 1”
5: Combined mode 2
6: Combined mode 3
7: Combined mode 4
8: Combined mode 5
00-17
P.97
Second target
frequency
selection
0: Frequency set by built-in keypad
0
59
1: Frequency set by RS485 communication
2: Frequency set by analog input
00-19
P.35
Communication
mode selection
0: In communication mode, run signal and frequency is given
by communication.
0
59
1: In communication mode, run signal and frequency is given
by external signal.
00-21
P.300
Motor control
mode selection
0Induction motor V/F control
0
60
1Reserved
2Induction motor simple vector control
00-23
P.186
Motor types
selection
0: Normal Duty (ND), on fan and pump duty type.
1
60
1: Heavy Duty (HD), apply to other duties.
00-24
P.189
50Hz/60Hz switch
selection
0: Frequency related parameter default value is 60Hz.
0
61
1: Frequency related parameter default value is 50Hz.
1
00-25
P.990
Parameter display
mode setting
0: Parameter is displayed in group mode
0
61
1: Parameter is displayed in sequence P mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SC3 Series and is the answer not in the manual?

Shihlin electric SC3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSC3 Series
CategoryInverter
LanguageEnglish

Related product manuals