Digital input/ output parameter group 03
PARAMETER DESCRIPTION 88
Group
Parameter
Number
Name
Setting Range
Default
Page
03-17
P.157
Digital input terminal filter
time
02000
4
95
03-18
P.158
Digital input terminal enable
when power on
0: When power on digital terminals work directly
0
96
1: When power on digital terminals work after
switch off then on
03-20
P.41
Output frequency detection
sensitivity
0100.0%
10.0%
96
03-21
P.42
Output frequency detection
for forward rotation
0650.00Hz
6.00Hz
96
03-22
P.43
Output frequency detection
for reverse rotation
0650.00Hz
99999
96
99999: Same as the setting of 03-21(P.42)
03-23
P.62
Zero current detection level
0200.0%
5.0%
97
99999: Off
03-24
P.63
Zero current detection time
0.05100.00s
0.50s
97
99999: Off