DL100 – CANopen
®
Distance measuring device
OPERATING INSTRUCTIONS

Table of Contents

Questions and Answers

  • A
    Angela MooreSep 8, 2025
    What to do if eLevel error appears on SICK DL100?
    • M
      Michael RochaSep 8, 2025
      If the current damping value is below the warning threshold on your SICK Measuring Instruments device (eLevel), you should: * Clean external lens surfaces like the reflector and the lens. * Decrease the distance between the measuring device and the reflector. * Use a distance measuring device with a higher range.
  • M
    Manuel PriceSep 7, 2025
    Why are LED BF flashing red and LED SF lit red on SICK Measuring Instruments?
    • S
      suttonchristianSep 7, 2025
      If the LED BF flashes red and the LED SF is lit red on your SICK Measuring Instruments device, it means the device (slave) is not configured or not configured correctly, and no data is being exchanged. You should configure the device and check the configuration.
  • H
    Heather BradfordAug 22, 2025
    How to troubleshoot SICK Measuring Instruments displaying '0000'?
    • A
      Annette MccoyAug 22, 2025
      If the SICK Measuring Instruments display shows "0000", it could be due to several reasons: * The measuring device's light spot isn't hitting the reflector. To fix this, correct the alignment between the measuring device and the reflector. * There's an obstacle in the light path. Remove any obstacles blocking the light. * The distance between the device and the reflector exceeds the maximum scanning range. Decrease the distance or select a device with a larger scanning range.
  • L
    laura39Sep 4, 2025
    What to do if ePlb error appears on SICK DL100?
    • P
      Paul JoyceSep 4, 2025
      If the measured value is not plausible (ePlb) on your SICK Measuring Instruments, it may be because the light path between the measuring device and reflector is interrupted or due to optical interferences. To resolve this: * Observe the light spot on the reflector to ensure it doesn't move from the reflector. Re-align the measuring device and reflector if needed, or use a larger reflector. * Remove any optical interferences, and re-align the distance measuring device and reflector.
  • J
    johnsonmarkSep 3, 2025
    What to do if 'Device error' appears on SICK Measuring Instruments?
    • K
      Karen JimenezSep 3, 2025
      If you see the 'Device error' on your SICK Measuring Instruments, it could be due to hardware issues or the internal device temperature being outside the permissible range. Here's what you can do: * Check the supply voltage and wiring. * Switch the supply voltage on and off. * Wait for the warm-up phase or let the device cool down. * Check the ambient temperature and improve ventilation if needed. * Shield against radiation heat by shading the device from direct sunlight. * Consider using a device with heating for low ambient temperatures or cooling housings for high temperatures. * If the problem persists, send the measuring device in for repair.
  • A
    Audrey JimenezSep 1, 2025
    How to fix '0000' value on SICK DL100 Measuring Instruments display?
    • B
      Brandon GarrisonSep 2, 2025
      If the display of SICK Measuring Instruments shows "0000", it might be because: * The measuring device's light spot does not hit the reflector. Correct the alignment between the measuring device and the reflector. * There is an obstacle in the light path. Remove any obstacles from the light path. * The distance between the distance measuring device and the reflector exceeds the maximum scanning range. Decrease the distance or select a device with a larger maximum scanning range.
  • J
    jeremy62Aug 31, 2025
    What to do if wTemp error appears on SICK DL100?
    • M
      Monica FordAug 31, 2025
      If the internal temperature of the SICK Measuring Instruments device is close to the permissible range: * Check the ambient temperature and improve ventilation if applicable. * Shield against radiation heat, e.g. share the measuring device in case of direct solar irradiation. * Use device with heating at low ambient temperatures. * Use cooling housings for high ambient temperatures.
  • D
    Daniel CameronAug 30, 2025
    What to do if eTemp error appears on SICK Measuring Instruments?
    • S
      Stephen PetersenAug 30, 2025
      If the internal temperature of the SICK Measuring Instruments device is outside the permissible range, take the following steps: * Check the ambient temperature and improve ventilation if possible. * Shield against radiation heat, for example, shade the measuring device in case of direct solar irradiation. * Use a device with heating at low ambient temperatures. * Use cooling housings for high ambient temperatures.
  • S
    Sheri JonesAug 28, 2025
    What to do if LED PWR is off but the display is lit on SICK DL100?
    • E
      Emily TaylorAug 29, 2025
      If the LED PWR is not lit but the display is on for your SICK Measuring Instruments, the measuring device may be defective. Send the device in for repair.
  • J
    Jessica HernandezAug 27, 2025
    What does 'wLaser' mean on SICK DL100?
    • D
      Dana ClarkAug 27, 2025
      The error message 'wLaser' on your SICK Measuring Instruments means that the measurement laser is still working but is nearing the end of its service life. Keep a replacement device ready.

Summary

Operating Instructions DL100 - CANopen

Important Safety Notes

Critical safety information for device operation, including laser safety.

General Information

Basic details about the manual, symbols, liability, delivery, and service.

Safety Guidelines

Comprehensive safety rules, intended/non-intended use, and personnel requirements.

Device Identification

Information for identifying the device, including the type label.

Setup and Functionality

Guidance on physical setup, operational principles, display, and controls.

Transport and Storage

Procedures for safe transport, inspection, and storage of the device.

Mounting Instructions

Detailed steps and considerations for installing the distance measuring device.

Electrical Connection

Safety precautions and diagrams for connecting the device electrically.

Operation of the Measuring Device

Instructions for device operation, parameter selection, and value changes.

Operation via Ethernet Interface

Configuration and operation using the Ethernet interface and SOPAS ET.

CANopen Interface

Comprehensive guide to CANopen communication, configuration, and objects.

Cleaning and Maintenance

Procedures for cleaning and routine maintenance of the device.

Troubleshooting Guide

Diagnosing and resolving common issues using LED status, warnings, and errors.

Repair and Technical Data

Information on repair policies and detailed technical specifications.

Device Accessories

Details on available accessories like reflectors, cables, and mounting systems.

Menu Structure

Visual representation of the device's navigation hierarchy and parameters.

SICK DL100 Specifications

General IconGeneral
Wave length650 nm
Resolution0.1 mm
Output signalAnalog
Supply voltage10 V DC ... 30 V DC
Beam Diameter3 mm
Operating Temperature-10 °C ... +50 °C
Storage Temperature-25°C to +70°C
Power SupplyDC