Setup
3.11 View 4
FST020 Function manual
106 Function Manual, 09/2017, A5E42949526-AA
If Single Value or Dosing is selected,
must be configured.
If Three Values is selected,
,
and
must be configured.
If Totalizer or 1 Value and Graph is selected,
,
and
must be configured.
If 1 Value and Bargraph is selected,
must be configured.
If Six Values or Six Diagnostic Values is selected,
,
,
,
,
, and
must be
configured.
Setup → Display → View 4 → View
The display
can be selected. This process value is shown in all view
types.
Setting
Transmitter internal temperature; Ch3 value;
Ch4 value; Reynolds number; RxGain up path
1; RxGain down path 1; SNR up path 1; SNR down path 1; Sound velocity path 1; Flow
velocity path 1; Delta time path 1; Travel time up path 1; Travel time down path 1; Correla-
tion factor path 1; Percentage of bursts accepted path1; Peak amplitude up path 1; Peak
amplitude down path 1; Min acc travel time path 1; Min acc travel time path 1; Max acc
Setup → Display → View 4 → 1st value
The display
can be selected.
Setting
Transmitter internal temperature; Reynolds number; RxGain up path 1; RxGain down path
1; SNR up path 1; SNR down path 1; Sound velocity path 1; Flow velocity path 1; Delta
time path 1; Travel time up path 1; Travel time down path 1; Correlation factor path 1; Per-
centage of bursts accepted path1; Peak amplitude up path 1; Peak amplitude down path 1;
Min acc travel time path 1; Min acc travel time path 1; Max acc travel time path 1