Setup
3.1 Sensor settings
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA
27
3.1.6.6
Sensor inactive wedge
Description
The part of the wedge that is not part of the sound path. Access level: Expert user only.
Setting
0.0 m to 0.05 m
Default
0.00076 m
Related
Path
Setup Sensor settings Sensor settings Sensor inactive wedge
3.1.6.7
Sensor fixed time
Description
Fixed time in sensor wedge. Access level: Expert user only.
Setting
2.0 x 10
-6
s to 200.0 x 10
- 6
s
Default 10.61 x 10
-6
s
Related
Path
Setup Sensor settings Sensor settings Sensor fixed time
3.1.6.8
Mounting hole offset
Description
Distance between spacer hole and sensor front face.
Setting 0.0 m to 0.05 m
Default
0.00953 m
Related
Path
Setup Sensor settings Sensor settings Mounting hole offset
3.1.6.9
Spacing offset
Description
Sensor spacing offset
Setting
MIN; NOM; MAX and A,B, C, D for High Temperature sensors
Default
MIN