Setup
3.13 View 6
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA
117
Related
This parameter is only available if
View
is set to Six Values or Six Diagnostic Values.
Path
Setup Display View 6 5th Process Value
3.13.8
6th process value
Description
The display
6th Process Value
can be selected.
Setting Mass flow; Volume flow; Density; Fluid Temperature; Totalizer 1
Default
Totalizer 1
Related
This parameter is only available if
View
is set to Six Values or Six Diagnostic Values.
Path
Setup Display View 6 6th Process Value
3.13.9
Trend scale mode
Description
The
Trend Scale Mode
can be selected with automatic scaling or fixed scaling.
Setting
Auto; Fixed
Default
Auto
Related
This parameter is only available if
View
is set to Totalizer or 1 Value and Graph.
If Fixed is selected,
Trend Scale Lower Limit
and
Trend Scale Upper Limit
must be
configured.
Path
Setup Display View 6 Trend Scale Mode
3.13.10
Trend log time window
Description
The
Trend log time window
logging period (time axis length) can be selected.
Setting
1 Minute; 5 Minutes; 15 Minutes; 30 Minutes; 1 Hour; 2 Hours; 3 Hours
Default
5 Minutes