Setup
3.4 Inputs and outputs
FST020 Function manual
62 Function Manual, 09/2017, A5E42949526-AA
Setting Process value = Mass flow: 0.00 kg to +9999997952 kg
Process value = Volume flow: 0.00 m³ to +9999997952 m³
Default Process value = Mass flow: 0.00 kg
Process value = Volume flow: 0.00 m³
Related
Path
Setup Totalizers Totalizer 1 Alarm and warning limits Hysteresis
3.4
Inputs and outputs
The available configuration of the hardware functionality of input and output is described in
the following table.
Table 3- 1 Hardware and software configuration of the input/output channels
Channel
HW configuration
(fixed when ordering)
SW configuration
available to the user
1
Modbus
Modbus
2 Signal output Outputs:
Current output (0/4-20 mA)
3 Relay output Status Output:
Alarm class
Alarm item
NAMUR status signals
4 Signal input/output Outputs:
Frequency ouput
Pulse output
Current output
All four channels can be configured as current output.
Current output configuration
The following process values can be assigned to the current output:
Volume flow
Mass flow
Sound velocity
Flow velocity
Density