Loading...
Setup
3.9 View 2
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA
97
Related
If Single value or Dosing is selected,
1st process value
must be configured.
If Three values is selected,
1st process value
,
2nd process value
and
3rd process value
must be configured.
If Totalizer or 1 value and graph is selected,
1st process value
,
Trend scale mode
and
Trend
log time window
must be configured.
If 1 value and bargraph is selected,
1st process value
must be configured.
If Six values or Six diagnostic values is selected,
1st process value
,
2nd process value
,
3rd
process value
,
4th process value
,
5th process value
, and
6th process value
must be
configured.
Path
Setup Local display View 2 View
3.9.3
1st value
Description
The display
1st Process Value
can be selected. This process value is shown in all view
types.
Setting
Volume flow; Mass flow; Flow velocity; Sound velocity; Density; Kinematic viscosity; Total-
izer 1; Medium temperature
Default
Volume flow
Related
Path
Setup Local display View 2 1st value
3.9.4
2nd process value
Description
The display
2nd Process Value
can be selected.
Setting
Mass flow; Volume flow; Density; Fluid Temperature; Totalizer 1
Default
Density
Related
This parameter is only available if
View
is set to Three Values, Six Values or Six Diagnostic
Values.
Path
Setup Display View 2 2nd Process Value

Table of Contents