Maintenance and diagnostics
4.4 Diagnostics
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA
141
4.3.3.4.2 Serial number (expert)
Description
Only Siemens authorized personnel may replace spare parts.
Setting
Cancel; OK
Default
Cancel
Path
Maintenance and diagnostics Maintenance Electronic part identification Sensor
cassette Serial number
4.4
Diagnostics
4.4.1
Sensor
4.4.1.1
Receiver signal
Description
Receiver signal
Path
Maintenance and diagnostics Diagnostics Sensor Receiver signal
4.4.1.2
Reynolds number (read only)
Description
Calculated Reynolds number.
Path
Maintenance and diagnostics Diagnostics Sensor Reynolds number
4.4.1.3
Path 1
4.4.1.3.1 RxGain up (read only)
Description
Rx gain of upstream signal.
Path
Maintenance and diagnostics Diagnostics Sensor Path 1 RxGain up