Operation
7.1 Operation
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
161
Copying parameter data sets from the memory card to non-volatile memory
There are two ways of copying parameter data sets from the memory card to non-volatile
memory:
The system is switched off
1. Insert a memory card containing a parameter data set with the index 0 into the CUD.
2. Switch on the system. The new parameter data set will be copied to the ROM
automatically. The parameter data set with the index 0 which was previously in the ROM
will be overwritten.
3. The system will then boot with the new parameter data set.
The system is switched on
The user starts data transmission from the memory card to the ROM with parameters p0802,
p0803 and p0804:
p0804 = 1
p0802 = (0 ... 100) as source from the memory card and p0803 = (0/10/11/12) as target to
the ROM.
Note
The parameter data set in the ROM is overwritten durin
g system start-up. If a memory card
with a parameter data set is inserted when the system is switched on, the parameter data set
with the index 0 in the ROM will be overwritten by the new one with the index 0 on the
memory card.