Operation
7.1 Operation
SINAMICS DCP
166 Operating Instructions, 09/2019, A5E34382853K
Note
A connector input (CI) cannot be interconnected to any connector output (CO, signal
source). The same applies for a binector input (BI) and binector output (BO).
"Data type" in the parameter list provides information ab
out the data type of the parameter
and the data type of the BICO parameter for each CI and BI parameter.
For CO and BO parameters, only the data type of the BICO parameter is given.
Notation:
•
BICO input data type: Parameter data type / BICO parameter data type
Example: Unsigned32/Integer16
•
Data type, BICO output: BICO parameter data type
Example: FloatingPoint32
The possible interconnections between the BICO input (signal sink) and BICO output (signal
source) are listed in the table titled "Possible combina
tions
for BICO interconnections", which
can be found in the "Explanations on the parameter list" chapter of the SINAMICS DCP List
Manual.
The BICO parameter interconnection can be implemented in different command data sets
(CDS). The different interconnections are activated by switching data sets. Interconnections
across drive objects are also possible.
Note
Process data is transferred be
tween SINAMICS DCP and a higher-level control system in a
standardized form via the fieldbus.
More detailed information
is provided in Chapter "Telegrams and process data (Page 187)"
in Section "Scaling BICOs".