EasyManua.ls Logo

Siemens sinamics dcp - Page 211

Siemens sinamics dcp
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
7.4 Communication according to PROFIdrive
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
209
Information about the parameter request:
Request reference:
The value is selected at random from the valid value range. The request reference
establishes the relationship between request and response.
Request ID:
02 hex This identifier is required for a write request.
Drive object No.:
02 hex The parameters are written to drive 2.
Number of parameters
04 hex The multi-parameter request comprises four individual parameter requests.
1st parameter address ... 4th parameter address
Attribute:
10 hex The parameter values are to be written.
Number of elements
01 hex One array element is written.
Parameter number
Specifies the number of the parameter to be written to (p0840, p0852, p55050, p50401).
Subindex:
0 dec ID of the first array element.
1st parameter value ... 4th parameter value
Format:
07 hex Data type, unsigned32
08 hex Data type, floating point
Number of values:
01 hex A value is written to each parameter in the specified format.
Value:
BICO input parameter: Enter signal source
Adjustable parameter: Enter value