Operation
7.11 Closed-loop control
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
331
Load profile "low overload" (p55080 = 2)
The "Low overload" load profile is only available for 120 kW devices.
With this load profile, the device can be operated with a load of 150 % of the rated current
for approximately 6.7 s.
For sufficiently high voltages, the device power correspondingly increases.
For longer overload times, the device shuts down and outputs fault F60530.
Figure 7-62 "Low overload" load cycle - example: Load with 150 %