CUD - Response of LEDs during ramp-up (following POWER ON)
Table 7- 77 Ramp-up
Red
Red Off Off BIOS error -
Red
Red
Off Off File error Memory card not present or
flash file system faulty
Red Orange
Off Off Firmware loading DP1 flashing without specific flashing
Red
Red
Off Off CRC error Firmware checked, CRC error
Response of the LEDs after ramp-up
Table 7- 78 CUD - Description of the LEDs after ramp-up
RDY (READY) - Off Electronic power supply is missing or outside
permissible tolerance range.
Check power supply
Green Continuous
The component is ready for operation. No errors
-
0.5 Hz
flashing
Commissioning/reset -
2 Hz flash-
ing light
Writing to memory card or internal flash memory
The electronic power supply for the SINAMICS
DCP must not be switched off during this write
process.
Switching off the electronic power supply can
lead to the loss of the parameter assignments.
See also Chapter "Memory card functions
-
Red 2 Hz flash-
General errors Check parameteriza-
Orange 0.5 Hz
flashing
Updating the firmware of the DRIVE-CLiQ com-
ponents.
–