EasyManua.ls Logo

Siemens sinamics dcp - Page 95

Siemens sinamics dcp
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection
5.6 Additional system components
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
93
X521 analog inputs
Table 5- 26 X521 terminal strip
Connector
Terminal
Designation
1)
Technical specifications
1
AI 0+
The analog inputs can be toggled between
current and voltage input using switches
S5.0 and S5.1
As voltage input:
-10 V to +10 V; R
i
= 100 kΩ
Resolution: 11 bits + sign
As current input:
R
i
= 250 Ω
Resolution: 10 bits + sign
2
AI 0-
3
AI 1+
4 AI 1-
5
P10
Auxiliary voltage
:
P10 = 10 V
N10 = -10 V
Current-carrying capacity: max. 3 mA
Sustained short-circuit-proof
6
M
7
N10
8 M
1)
AI: Analog inputs; P10/N10: Auxiliary voltage; M: Ground reference
NOTICE
Damage or malfunctions through impermissible voltage values
If a current exceeding ±35 mA flows through the analog current input, then the component
could be destroyed.
The common mode range must not be violated in order to avoid incorrect analog-digital
conversion results.
• The input voltage may only be in the range between -30 V and +30 V (destruction limit).
• The common mode voltage may only be in the range between -10 V and +10 V (error
limit).
• The back EMF at the auxiliary voltage connections may only be in the range between -
15 V and +15 V.
Note
The power supply for the analog inputs can be taken internally or from an external power
supply unit