EasyManua.ls Logo

Siemens SIPROTEC 7UM62 - Page 607

Siemens SIPROTEC 7UM62
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.8 Information List
SIPROTEC, 7UM62, Manual
C53000-G1176-C149-7, Release date 03.2010
607
5519 Stage df4/dt picked up (df4/dt
pickup)
df/dt Protect. OUT * on off * LED BO 72 12 2 Yes
5520 Stage df1/dt TRIP (df1/dt TRIP) df/dt Protect. OUT * on * LED BO 72 13 2 Yes
5521 Stage df2/dt TRIP (df2/dt TRIP) df/dt Protect. OUT * on * LED BO 72 14 2 Yes
5522 Stage df3/dt TRIP (df3/dt TRIP) df/dt Protect. OUT * on * LED BO 72 15 2 Yes
5523 Stage df4/dt TRIP (df4/dt TRIP) df/dt Protect. OUT * on * LED BO 72 16 2 Yes
5533 >BLOCK inadvertent energ. prot.
(>BLOCK I.En.)
Inadvert. En. SP * * * LED BI BO
5541 Inadvert. Energ. prot. is swiched
OFF (I.En. OFF)
Inadvert. En. OUT on
off
**LEDBO72311Yes
5542 Inadvert. Energ. prot. is
BLOCKED (I.En. BLOCKED)
Inadvert. En. OUT on
off
on off * LED BO 72 32 1 Yes
5543 Inadvert. Energ. prot. is ACTIVE
(I.En. ACTIVE)
Inadvert. En. OUT on
off
**LEDBO72331Yes
5546 Release of the current stage
(I.En. release)
Inadvert. En. OUT on
off
**LEDBO72341Yes
5547 Inadvert. Energ. prot. picked up
(I.En. picked up)
Inadvert. En. OUT * on off * LED BO 72 35 2 Yes
5548 Inadvert. Energ. prot. TRIP (I.En.
TRIP)
Inadvert. En. OUT * on m LED BO 72 36 2 Yes
5553 >BLOCK SEF with 3.Harmonic
(>SEF 3H BLOCK)
SEF 3.Harm. SP * * * LED BI BO
5561 SEF with 3.Harm. is switched
OFF (SEF 3H OFF)
SEF 3.Harm. OUT on
off
**LEDBO72511Yes
5562 SEF with 3.Harm. is BLOCKED
(SEF 3H BLOCK)
SEF 3.Harm. OUT on
off
on off * LED BO 72 52 1 Yes
5563 SEF with 3.Harm. is ACTIVE
(SEF 3H ACTIVE)
SEF 3.Harm. OUT on
off
**LEDBO72531Yes
5567 SEF with 3.Harm. picked up (SEF
3H pick.up)
SEF 3.Harm. OUT * on off * LED BO 72 54 2 Yes
5568 SEF with 3.Harm. TRIP (SEF 3H
TRIP)
SEF 3.Harm. OUT * on m LED BO 72 55 2 Yes
5571 >BLOCK startup O/C protection
(>BLOCK O/C St)
O/C Startup SP * * * LED BI BO
5572 Startup O/C protection is
switched OFF (O/C Start OFF)
O/C Startup OUT on
off
**LEDBO72621Yes
5573 Startup O/C protection is
BLOCKED (O/C Start BLK)
O/C Startup OUT on
off
on off * LED BO 72 63 1 Yes
5574 Startup O/C protection is ACTIVE
(O/C Start ACT)
O/C Startup OUT on
off
**LEDBO72641Yes
5575 Startup O/C phase L1 picked up
(O/C Start L1 PU)
O/C Startup OUT * on off * LED BO 72 65 2 Yes
5576 Startup O/C phase L2 picked up
(O/C Start L2 PU)
O/C Startup OUT * on off * LED BO 72 66 2 Yes
5577 Startup O/C phase L3 picked up
(O/C Start L3 PU)
O/C Startup OUT * on off * LED BO 72 67 2 Yes
5578 Startup O/C protection TRIP (O/C
Start TRIP)
O/C Startup OUT * on * LED BO 72 68 2 Yes
5581 >BLOCK Vector Jump (>VEC
JUMP block)
Vector Jump SP * * * LED BI BO
5582 Vector Jump is switched OFF
(VEC JUMP OFF)
Vector Jump OUT on
off
**LEDBO72721Yes
5583 Vector Jump is BLOCKED (VEC
JMP BLOCKED)
Vector Jump OUT on
off
on off * LED BO 72 73 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Related product manuals