Hydro:Evolved User Manual
Page 284 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
CT Switch input (SF1) lost.
CT Escape Hatch input (SF2) lost.
CT Car Safeties input (SF3) lost.
COP IC Stop input (SF2) lost.
COP Fire Stop Switch input (SF3) lost.
MR board will not fault. It will either refuse
to run and issue an alarm, or the car mode
will be Invalid Insp.
Attempt to move on hoistway access
inspection is invalid combination of locks
open and access switches, or multiple
access switches are active at the same
time.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Lock input lost, door zone input lost, and
locks are not bypassed due to hoistway
access or hall bypass switch.
Gate switch input lost, door zone input
lost, and car doors are not bypassed due to
hoistway access or car door bypass switch.
Gate switch input lost, door zone input
lost, and car doors are not bypassed due to
hoistway access or car door bypass switch.
Preflight failed for the MR 501 (Pit
Inspection) input.
Preflight failed for the MR 502 (Landing
Inspection) input.
Preflight failed for MR BFL input.
Preflight failed for MR TFL input.