Configuration Menu
Reference voltage section
In addition to the current measured by the CT, a reference voltage is needed for the power output calcula-
tion. This reference voltage can either be
recorded via the inverters and/or calculated by the Solar-Log™
or set in the box reference voltage [V].
If the Solar-Log™ does not receive voltage values from the inverters (for example during night), an average
value is calculated and used.
By activating the
Always use stored voltage button, the value entered in the reference voltage [V] input
box is always used for the power output calculation.
Note!
The reference voltage value is predefined by the country settings. Please check this
value.
It is best to measure the reference voltage and enter this value.
During the
Device Detection process, the CT defined here is recognized as a meter and can be adjusted
and named accordingly in the meter configuration menu under
Configuration | Devices | Configuration.

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals