Configuration Menu
16.10.5 Control Logics Definition - Operating Mode Generator
Various control logics can be defined with the input boxes. (See the Smart Energy Manual for more details
– available for download from our website –
The individual boxes can be combined differently, depending on the control is used.
The following rules can be selected from the Category box:
Power from the grid
Other
Power from the grid
The following types can be configured under the Grid Power category:
Power from the grid
Power from the grid and Time Control
Power from the grid and Runtime Control
Power from the grid
The following production definition (production) can be selected in the Grid Power section:
Configured nominal power:
Production is calculated from the configured nominal power for the contacts and the switch state.
The nominal power can be defined in the Module Fields, Power Output and Descriptions section of
the Configuration | Devices | Configuration. If it is available, the current state is used for the calcu
-
lation; otherwise, the target state is used. .
Measured value from the contacts (can only be selected if at least one contact that provides out-
put values has been assigned to the switching group. This depends on the hardware used and can
be viewed by clicking on the magnifying glass icon in the hardware section under Configuration |
Smart Energy | Switching groups):
Production is determined by the measured production from the individual contacts as long as the-
se values are provided. This is determined by the configured nominal power for contacts that do
not provide these values or when communication is offline.
Production meter:
Production is determined by a separate production meter that has to be detected as a device.
Section Grid Power
After the production determination has been selected, the threshold values have to be configured in the
last step.
Switching on at grid power [W]
Switching hysteresis [W]
The switching hysteresis is to prevent the switch from being permanently turned on/off at the
threshold. It is recommended to have a hysteresis of 100 to 1000 W depending on the switch-on
threshold.
Switching off below production [W] (This value is grayed out and cannot be manually modified. It
is calculated from the „Switching on at grid power [W]“ value minus the „Switching hysteresis (W)“
value.)
Power from the grid and Time Control:
This production determination is identical to that of the grid power
After selecting the production determination, the following sections are to be configured:
Power from the grid
Time

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals