Component Course of action
Battery
Check that the interlock is in good condition and is
working correctly.
Lock the battery.
Ensure that the battery is approved for use in po-
tentially explosive areas.
Battery male connector and plug connec-
tion
Inspect the battery male connector and the plug
connection for moisture or any foreign objects that
may have become lodged and remove as necessa-
ry, e.g. using compressed air.
Perform a visual inspection for integrity and de-
formation.
Check the contacts.
Have damaged battery male connectors replaced
by the authorised service centre.
Coupling pin, tow coupling (variant)
Make sure that only a coupling pin that is ap-
proved for use in potentially explosive areas is
used.
Perform a visual inspection for deformation and
wear (for example: bent, torn, broken).
Check the securing bush in the counterweight for in-
tegrity and to ensure that it is working correctly.
Check that the linchpin is present and working cor-
rectly (chain, rope, split pin).
Labelling, adhesive label
Check that labels are present and intact/legible.
Replace damaged or missing adhesive labels in ac-
cordance with the section entitled "Labelling points".
Driver's seat, seat belt Check the integrity and function.
Display-operating unit: assistance systems
Check the function of the "assistance systems" lis-
ted in the menu. Refer to the section entitled "Func-
tion checking of assistance systems".
Lighting, warning units
Check the integrity and function.
Check the setting of the warning zone light.
Antistatic belt (3), corona electrode (4)
(See the following illustration.)
Perform a visual inspection for integrity.
Ensure cleanliness.
Make sure that the antistatic belt(3) is still long
enough to touch the ground in all situations.
The discharge wires of the corona electrode (4)
must not touch the ground. The wires discharge the
energy to the air.