INDEX OF LISTS, SUB-LISTS AND POSITIONS
1/1 OCTAVE Selection of 1/1 OCTAVE analysis, position of FUNCTION sub-list 4 - 39
1/3 OCTAVE Selection of 1/3 OCTAVE analysis, position of FUNCTION sub-list 4 - 58
3 PROFILES Measurement results presentation mode (numerical), position of DISPLAY sub-list 5 - 1
ACC Setting the reference level for acceleration measurements, position of
REFERENCE LEVEL sub-list 5 - 26
ANALOG Type of input / output devices, sub-list of EXT. I/O SETUP 5 - 23
AUTO SAVE Controlling of measurement results savings, position of SAVE OPTIONS sub-list 5 - 42
AXIS SETUP Assign axis of accelometer to the number of channels, sub-list of HAV/WBV DOSE
list 5 - 33
BACKLIGHT Setting the backlight parameters, sub-list of DISPLAY list 5 - 14
BATTERY Checking the state of the internal battery, position of DISPLAY list 5 - 12
BRIGHTNESS Setting the brightness of the backlight, position of BRIGHTNESS sub-list 5 - 14
BUF. STEP Setting time between two writings to the buffer’s file, position of
MEASURE SETUP sub-list 4 - 25
BUFFER VIEW Selection of the buffer’s file to the screen presentation, sub-list of DISPLAY list 5 - 8
BUFFER Selection of 1/1 OCTAVE analysis result to be saved in the buffer’s file, position of
SPECTRUM sub-list 4 - 47
BUFFER Selection of 1/3 OCTAVE analysis result to be saved in the buffer’s file, position of
SPECTRUM sub-list 4 - 78
BUFFERS Selection of the result to be saved in the buffer’s file, position of BUFFERS
SETUP sub-list 4 - 30
CAL. LEVEL Setting the level of the calibrator’s signal, position of CALIBRATION sub-list 4 - 4
CALIBRATION Calibration of sound measurement channel, sub-list of FUNCTION list 4 - 4
CATALOGUE Controlling the contents of the memory, position of FILE list 5 - 49
CHANNEL x Setting parameters in a profile of SLM, sub-list of CHANNELS SETUP sub-list 4 - 25
CHANNELS SETUP Setting parameters in profiles and for octave analysis, sub-list of INPUT list 4 - 25
CLEAR SETUP Return to the factory made settings, position of SETUP list 5 - 25
CLEAR BUFFER Removing all files with the results from buffer’s memory, position of FILE list 5 - 48
CLEAR Clearing the coefficients of the user filters, position of USER FILTER sub-list 5 - 21
CONTRAST Setting the contrast of the screen, position of DISPLAY list 5 - 13
DAILY EXPOSURE Displaying the daily exposure in DOSE mode, sub-list of HAV CALCULATOR sub-list5 - 66
DAILY RESULTS Displaying the daily exposure and daily dose in DOSE mode, sub-list of WBV
CALCULATOR sub-list 5 - 66
DEFRAGMENTATION Memory merging, position of FILE list 5 - 47
DELETE ALL Removing all files from instrument’s memory, position of FILE list 5 - 46
DELETE Removing a file with the results from instrument’s memory, position of FILE list 5 - 45
DETECTOR Selection of the RMS detector, position of CHANNEL x sub-list 4 - 29
DIGITAL IN Type of input / output devices, sub-list of EXT. I/O SETUP 5 - 23
DIGITAL OUT Type of input / output devices, sub-list of EXT. I/O SETUP 5 - 23
DIL Setting the reference level for displacement measurements, position of
REFERENCE LEVEL sub-list 5 - 27
DISPLAY MODES Selection of the ways of measurement results presentation, sub-list of DISPLAY list 5 - 1
DISPLAY SCALE Selection of the scale in graphical results presentations, sub-list of DISPLAY list 5 - 4
DISPLAY Data available on the screen, main list (function of the push-button) 5 - 1
DOSE Selection of DOSE measurements, position of FUNCTION sub-list 5 - 32
DYNAMIC Scaling of the vertical axis of the graphical presentation, position of DISPLAY SCALE
sub-list 5 - 4