5.3 Reference Guide using RS-232C commands
107
This command reads the transmitter power of a tester.
CONF:SYS:RF:TX_POW <Value>
Description
This command writes the transmitter power of a tester.
Value
TX Power : 0 ~ -80, -30(default)
READ:SYS:RF:ATT?
Description
This command reads the “30dB RX Attenuator” state of a tester.
CONF:SYS:RF:ATT <Value>
Description
This command writes the “30dB RX Attenuator” state of a tester.
Value
30dB RX Attenuator : ON(default), OFF
READ:SYS:RF:AGC?
Description
This command reads the RX AGC(Automatic Gain Control) value of a tester.
CONF:SYS:RF:AGC <Value>
Description
This command writes the RX AGC(Automatic Gain Control) value of a tester.
Value
AGC : ON(default), OFF
READ:SYS:RF:RX_GAIN?
Description
This command reads the gain of RX amplifier of a tester.
CONF:SYS:RF:RX_GAIN <Value>
Description
This command writes the gain of RX amplifier of a tester. To make use of this command, send
“CONF:SYS:RF:AGC OFF” command prior to this command.
Value
RX gain : 10dB, 20dB(default), 30dB, 40dB, 50dB, 60dB, 70dB
READ:SYS:RF:10M_REF?
Description
This command reads the type of reference oscillator of a tester.
CONF:SYS:RF:10M_REF <Value>
Description
This command writes whether reference oscillator of a tester is internal or external. In order to use your
10MHz reference oscillator, user has to call this function with external reference oscillator parameter.
Value
Type of reference oscillator : INT(default), EXT
READ:SYS:DUT:PACK_TYPE?
Description