3.5 Operation Procedure (Measurement/Measurement2)
53
4. Power versus Channel: To access Pow-Chan screen, press M4 soft key. This
screen shows the channel power measures of every channels, 0~78.
Parameters
Range
Default
dB/div
0 ~ 20
10
Ref. Level (dBm)
-80 ~ 40
-80 + Path Loss ~ 40 + Path Loss
Start/Stop: When this menu is pressed the tests will
run once. When the menu is pressed again while the
tests are running, the tests will stop.
Up/Down Remote Tx: Increasing/Decreasing
the DUT TX power. This function is available
only when the DUT supports the power control
option. The step size depends on the DUT
specification (2~ 8 dB).
Line Markers: You can place line-shaped markers on the
screen to find the channels amplitude and set reference
amplitude. To activate a maker, press the Marker key
in sequence. An activated marker changes to a solid line.
Turn the knob to place the marker at the signal.
Readouts of markers channel and amplitude: The marker
readouts have the same color as the marker respectively.
dB/Div: Sets the vertical amplitude per
division
Test mode: Configures Bluetooth Test
Mode connection with DUT
Ref. Level: Specifies the amplitude reference
level. The top line of the display is the
reference level. All signals displayed are
reference to this line.