iCNC Performance
7-18 iCNC SETUP Manual 0-5401
SD4
SD5
CUT
ED1
ED3
- IHS Start activates
- Torch starts move down
- Torch rises to ignition height
- Height control res plasma
- Main arc signal from plasma
interrupts the delay (inbit 04 turns 1)
- Pierce Delay
- Machine cuts the part
- Wait for arc to
extinguish (inbit 04 turns 0)
- Move torch up
Outbit 7 ON
Outbit 7 ON
Outbit 7 ON
Outbit 7 OFF
Outbit 7 OFF
in04 interrupt
in04 interrupt
Machine moves to pierce point
Machine moves to next pierce point
Start Delay is referenced as SD and End delay is referenced as ED.
• Enabled Enable/Disable the Delay. In the example picture above SD1-3 are disabled as they are not used.
• ID Delay ID name.
• Outbits Set outbits that are active (ON) during the delay.
• Time Set the default delay time.
• Name Write a delay description.
• Visible Select is the delay visible in the process selection window.
• Editable Select can the delay time be edited in the process selection window.
* Select if the delay is shown in readjust cutting parameters.
• Interrupted Select is the delay interrupted or just a time based delay.
• Inbit Select the inbit that will be used for delay interruption. In the example picture inbit4 will interrupt SD4 delay when
it turns 1. Also ED1 will be interrupted when inbit4 turns back to 0.
• Polarity Set the inbit interrupt polarity.
• Start Not used with plasma cutting. See explanation from gas cutting example.