EasyManua.ls Logo

Toshiba Strata CTX - DKT3000 Settings and Features; FB Buttons Configuration

Toshiba Strata CTX
533 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Station
Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 5-21
Station
Data
Programs Used: 208, 210 and 216
Assign Timers, Paging and other related station data using the programs that follow.
1. Complete the Station Data
Record Sheets on page D-18.
2. From the Program Menu click
Station > Assignment.
3. Click on the Data tab (shown
right).
4. Enter a DN number in the
Primary DN field.
...or select an existing record by
clicking one of the following
buttons:
List view a summary list of
programmed DKTs.
Extended List view a
detailed list of programmed
DKTs.
Copy Enter a DN in the Primary DN field and click Copy. Enter a new DN to assign existing
Station Timer settings.
5. Select the desired values. See descriptions below.
6. Click Submit.
208 Station Timer Assignments
Prerequisite Program: 200 on page 5-1
Assigns timing parameters to Primary DNs.
FIELD DESCRIPTION
Primary DN Enter the Primary DN.
Possible values: Up to 5 digits (default = no value)
01 ABR Retry Count Enter the number of retry attempts made by ABR when dialing a busy telephone
number.
Possible values: 5~20 (default = 15)
02 ABR Retry Interval
Timer
Select the amount of time (in seconds) ABR waits between dialing attempts.
Possible values: 30~180 (default = 60)
03 ABR Recall Timer Select the number of seconds ABR will call back the station after receiving ring
back tone from the dialed number.
Possible values: 5~60 (default = 20)
04 Hold Recall Timer Select the number of seconds before a call is placed on hold recalls.
Possible values: 0~255 (default = 60)