Telephone Button Programming
200 Series Programs
Strata CTX Programming - Part 3:Telephone Button Programming 04/03 13-27
Telephone Button
Programming
200 Series Programs
Programs 200~202
Button Sequence Value(s) Summary
200
Station Data
,
+ROG
This command assigns stations to the system.
200-00 Primary DN
n,
+ROG
n = Up to 5 digits Primary DN (enter an existing PDN or enter a PDN you wish to create
for a new station).
200-01 PDN Equipment
Number
)%
, xxyyzz,
+ROG
xx = Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
Enter the PDN equipment number (xxyyzz). This is the cabinet, slot,
and circuit number of the ADKU, BDKU/BDKS, PDKU, or RSTU
interface PCB to which the the PDN is, or should be assigned.
Example: If the PDN should be a assigned to a BDKU in cabinet 5,
slot 2, circuit 3; enter 050203.
Cabinet numbers:
• CTX100: Select 01 for Base and Expansion cabinet.
• CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
• CTX100: Select 01~04 for Base slots and 05~08 for Expansion
slots.
• CTX670: Select 01~08 for Base slots and 01~10 for Expansion
slots.
yy = Slot (01~10)
zz = Circuit (01~16)
200-02 Station Type
)%
, n,
+ROG
n = 1. DKT
2. SLT
Station Type.
Note Select SLT to set up voice mail.
200-03 Circuit Type
)%
, n,
+ROG
n = 1. Extension
2. Voice Mail
Extension: Should be assigned to PDNs the are associated with
Digital or Standard telephones
Voice Mail: Should be assigned to PDNs associated with Voice Mail
RSTU circuits.
200-04 Station COS
• Day1 COS
• Day2 COS
• Night COS
)%
, n,
6SNU
, n,
6SNU
, n,
+ROG
n = 1~32 COS for Day1.
COS for Day2.
COS for Night.
200-05 Station DRL
• Day1 DRL
• Day2 DRL
• Night DRL
)%
, n,
6SNU
, n,
6SNU
, n,
+ROG
n = 1~16 DRL for Day1 (Used for Credit card calling).
DRL for Day2.
DRL for Night.
200-06 Station FRL
• Day1 FRL
• Day2 FRL
• Night FRL
)%
, n,
6SNU
, n,
6SNU
, n,
+ROG
n = 1~16 FRL for Day1.
FRL for Day2.
FRL for Night.
200-07 LCR Group
)%
, n,
+ROG
n = 1~16 Station LCR Group Number.