Trunks
315 T1 Trunk Card
6-20 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
315 T1 Trunk Card
Prerequisite Program: 100 on page 4-1
This command assigns T1 Trunk Card Data to the system.
1. Complete the Trunk Timer/DIT
Record Sheet on page D-27.
2. From the Program Menu, click
Trunk > T1. The T1 Trunk Card
Data Assignment screen displays
(shown right).
3. Enter T1 card location in Shelf/Slot
field (xxyy). The selected slot
requires a DTU Card.
xx = Cabinet 01~07
yy = Slot 01~10
...or click the following buttons:
List to view a summary list of programmed Trunks.
Copy to T1 trunk equipment.
4. Enter values for Program 315.
5. Click Submit.
FIELD DESCRIPTION
T1 Equipment
Location
Enter the RDTU PCB equipment location.
Possible values: xx = cabinet 01; yy =slot 03, 05, or 07
...or xx = cabinet 02~07; yy =slot 01, 03, or 05
Cabinet Select 01 for Base and Expansion cabinet (CTX100).
Select 01 for Base and 02~07 respectively for each Expansion
cabinet (CTX670).
Slot Select 01~04 for Base slots and 05~08 for Expansion slots
(CTX100).
Select 01~08 for Base slots and 01~10 for Expansion slots
(CTX670)
(default = no value)
01 Coding Format Select the Coding Format.
Possible values: None, PZC, B8ZS (default) or ZCS
02 Frame Format Select the Frame Format.
Possible values: SF Mode or ESF Mode (default)
04 Receive PAD Select the Receive PAD values.
Possible values: None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB
05 Send PAD Select the Send PAD values.
Possible values: None, Plus 6 dB, Plus 3 dB, Zero dB (default), Minus 3 dB, Minus
6 dB, Minus 9 dB, Minus 12 dB or Minus 15 dB