Telephone Button Programming
900 Series Programs
Strata CTX Programming - Part 3:Telephone Button Programming 04/03 13-99
Telephone Button
Programming
ISDN Trace Location
This program enables set up of ISDN protocol event trace collection conditions.
Program Number(s): 904
Prerequisite Program:
None
Reference: None
Access Sequence: Login to programming mode from your telephone button pad:
+ROG.
At the PASSWORD= prompt, Enter your password and press+ROG.
At the PROG= prompt enter  and press +ROG.
At the EQUIP= prompt enter the Shelf, Slot and Port numbers.
Notes
Shelf, Slot and Circuit number is entered in XXYYZZ format where Shelf is a two digit value from
01~07 corresponding to the Strata CTX Cabinet number, Slot is a two digit value from 01~10
corresponding to the Strata CTX Cabinets PCB slot number and Circuit is a two digit value from
01~04 corresponding to the Strata CTX PCB Slots circuit number.
Always use circuit 01 for RPTU.
1. Press
)% to run a LLCI Trace. Press the 6FUROO or 3DJH button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
2. Press
)% and set CCL3 Trace Level. Press the 6FUROO or 3DJH button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
3. Press
)% and set L2L3 Trace Level. Press the 6FUROO or 3DJH button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
4. Press
)% and set STATE Trace Level. Press the 6FUROO or 3DJH button to view Non, Brief, or
Detailed options. Enter 1~3 to determine Trace Level.
5. Press
)% and set ERRORS Trace Level. Press the 6FUROO or 3DJH button to view Non, Brief, or
Detailed options. Enter 1~3 to determine Trace Level.
6. Press
)% and set L2 Trace Level. Press the 6FUROO or 3DJH button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
7. Press
+ROG to execute.
8. Press
+ROG to return to the PROG= prompt.
9. Enter another program number to continue programming or press
+ROG again to exit programming
mode.
FB Name FB Summary Value LCD Prompt
LLCI 01 Level of collecting LLCI values. 1:None (no
information)
2:Brief (important
information)
3:Detailled (all
information)
1:NON
2:BRIEF
3:DETAILED
Layer 3 02 Level of collecting Layer 3 messages.
Layer 2 and 3
03 Level of collecting Layer 2 and Layer 3
messages.
State Transitions
04 Level of collecting State Transitions.
Errors
05 Level of collecting errors.
Layer 2 States 06 Level of collecting Layer 2 States.