Services
External Devices
9-48 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
External Devices
Door Phones
Programs Used: 507, 576 and 508
This command assigns Door Phone parameters.
1. Complete the “Door Phone
Assignment Record Sheet” on
page D-53.
2. From the Program Menu, click
Services > External Device > Door
Phones.
3. Enter Door Phone Number
...or click one of the following
buttons:
• List – View a summary list of
programmed Door Phones.
• Create – Assigns a new Door
Phone with default settings.
• Copy – Copies settings from an
existing Door Phone.
• Delete – Deletes a Door Phone.
4. Enter remaining Program 507 data.
5. Enter Program 576 data.
6. Enter Program 508 data.
7. Click Submit.
507 Door Phone Assignment
Prerequisite Program: None
This assignment configures Door Phone Control Boxes (DDCBs) and Door Phones (MDFBs). DDCBs can
be connected to ADKU, PDKU and/or BDKU interface PCBs. Up to three MDFBs can be connected to
one DDCB. A Door lock control relay may be assigned to the B output of the DDCB in place of a MDFB
door phone (see “508 Door Lock Control Assignment” on page 9-50).
FIELD DESCRIPTION
00 Door Phone Number Enter the door phone number.
Possible values: 1~6 (CTX100), 1~9 (CTX670 Basic),
1~24 (CTX670 Exp.), (default = no value)
Door phone numbering for both CTX100 and CTX670 is as follows:
• DDCB 1 provides door phone numbers 1~3, 2 can be a door phone or door
lock.
• DDCB 2 provides door phone numbers 4~6, 5 can be a door phone or door
lock.