515 View BIOU Control Relay Assignments
Prerequisite Program: 100 on page 4-1, and 105 on page 4-12
This assignment is used to view functions of the four control relays on each BIOU PCB set in Program 105
12 Night Relay and 18 Night Bell Relay; Program 508 Door Lock Control Assignment; and Program 503
19 BGM Mute Relay. The system allows up to two BIOU PCBs to provide a total of eight control relays.
The control relays can be configured as an external BGM mute control, Night Bell control, Night Mode
Control, and Door Lock Control.
Notes
● BIOU-1 relays are identified as Control Relays 1~4.
● BIOU-2 relays are identified as Control Relays 5~8.
1. From the Program Menu, click Services >
External Device > BIOU Relay Type.
2. Enter Program 515 data.
3. Click Submit.
FIELD DESCRIPTION
00 BIOU (1 or 2) Enter the BOIU PCB number.
Possible values: 1 or 2 (default = no value)
Note BIOU 1 and BIOU 2 are assigned in Program 100 - Card Assignment.
01 BIOU Relay 1 or 5
02 BIOU Relay 2 or 6
03 BIOU Relay 3 or 7
04 BIOU Relay 4 or 8
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
Possible values: Not Use, Ext Paging, Night Bell, Night Relay or Door Lock
(default = no value)
• NOT USE – if the relay is not used.
• PAGE MUTE – External BGM mute control activates during an external page
(see “503 Paging Devices Group Assignments” on page 9-53).
• NIGHT BELL – Night Bell control activates during the system Night Mode only
when incoming CO lines ring (see “102 Flexible Access Codes” on page 4-3).
• NIGHT RELAY – Night Mode Control activates continuously during the system
Night Mode (see “105 System Data” on page 4-12).
• DOOR LOCK – Door Lock Control activates when a telephone's Door Unlock
button is pressed (see “508 Door Lock Control Assignment” on page 9-50).