Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 5-1
Station
Station 5
This chapter provides Strata CTX station programming information for programmers using the CTX
WinAdmin programming interface.
Assignment
Programs Used: 200, 204, 214, 205, 213, 215, 208, 210, 216 and 502
The following programs assign station data.
Basic/200 Station Data
Prerequisite Program: 100 on page 4-1
This command assigns stations to the system.
1. Use the Basic Station Record Sheets on page D-11 to record your desired Station settings.
2. From the Program Menu, click
Station > Assignment.
3. Click on the Basic tab (shown
right).
4. Enter a DN number in the
Primary DN field
...or click one of the following
buttons:
List view a summary list of
programmed DNs.
Extended List view a
detailed list of programmed
DNs.
Create Assign a new DN
with custom settings by
entering a DN value. Press
OK, assign the PDN
Equipment No. and click
Submit.
Selective Copy Enter a DN in the Primary DN field and click Selective Copy to make a new DN
assignment with settings copied from the DN entered in the Primary DN field.
Delete Enter a Primary DN or a range of Primary DNs to delete and click OK.
Change DN Enter a DN in the Primary DN field and click Change DN. Enter the new DN
assignment and click OK.