Services
Networking
9-42 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
653 Private Route Choice Table Assignment
Prerequisite Program: None
Use this command to define a Private Route Choice Table. A Private Route Choice Table contains up to six
Route Definitions. The system will step through these Route Definitions in terminating hunt fashion to find
a route to the desired private networking node. There may be up to 64 Route Choice Tables.
654 Private Route Definition Table Assignment
Prerequisite Program: None
Use this command to define a Private Route Definition. A Private Route Definition consists of an OLG and
a pointer into the Private Digit Modification Table that contains the dialed digits to be deleted and/or
inserted before being communicated to the distant node.
655 Private Network Digit Modification Table Assignment
Prerequisite Program: None
This command assigns Digit Modification Tables for Private Networking.
FIELD DESCRIPTION
00 Pvt Ntwk Route Choice
Table Number
Select the Private Network Route Choice Table Number.
Possible values: 1~64 (default = no value)
01~06 Route Definition
Tables
Select Route Definition Tables 1~6 to be used for this Private Network Route
Choice.
Possible values: 1~64, 0 = delete (default)
FIELD DESCRIPTION
00 Private Network Route
Definition
Select the number of the Private Route Definition to be defined or deleted.
Possible values: 1~64 (default = no value)
01 Outgoing Line Group Select the OLG to be used by this route.
Possible values: 1~32 (CTX100), 1~50 (CTX670 Basic),
1~128 (CTX670 Exp.), 0 = delete (default = 0)
02 Digit Modification Table Select the Digit Modification Table to be used by this route.
Possible values: 1~64, 0 = delete (default)
FIELD DESCRIPTION
00 Private Network Digit
Modification Table
Select the Private Network Digit Modification Table to be defined.
Possible values: 1~64 (default = no value)
01 Deleted Digits Select the number of leading digits to be deleted.
Possible values: 1~10, 0 = delete (default)
02 Insert Leading Digits Select the leading digits to be inserted.
Possible values: Up to 23 digits (default = no value)