Trunks
ISDN
6-34 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
322 Called Number Table
Prerequisite Program: 306 on page 6-4
When calls are received from the PSTN, a Called Number is supplied as part of the Setup Message. This
Called Number may be used for directing the call to the appropriate service with Strata CTX.
FIELD DESCRIPTION
OLG Number OLG Number.
Possible values: 1~32 (CTX100), 1~50 (CTX670 Basic), 1~128 (CTX670 Exp),
(default = no value)
01 Source Type Specify the type of circuit used for outgoing calls: 1- PDN; 2- GCO; 3- Pooled Line.
Possible values: Primary DN (0~99999), Group CO (1~128) or Pool Line Group
(1~128); (default = no value)
02 Source Number Specify the number of the source type selected (PDN, GCO or Pooled Line).
Possible values: 1~32 (CTX100), 1~50 (CTX670 Basic), 1~128 (CTX670 Exp),
(default = no value)
03 DID Number Specify the number of digits received for reaching this service.
Possible values: Up to 7 digits (default = no value)
Note Destination Type and Destination must be entered before a DID number