System
I/O Device
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 4-29
System
801 Network Jack LAN Device Assignment
Prerequisite Program: 803 on page 4-27 and 804 on page 4-30.
This screen assigns Strata CTX LAN
parameters, enabling PC applications
to connect to the BECU network jack.
1. From the Program Menu click
System > I/O Device. The
Equipment Assignment screen
displays.
2. Click the LAN Device tab. 801
Network Jack LAN Device
Assignments screen displays
(shown right).
3. Enter Program 801 data.
FIELD DESCRIPTION
00 LAN Port Number Enter the port number of the LAN device to be assigned. Refer to 803 SMDR SMDI
CTI Port Assignments on page 4-27.
Possible values: 1~12 (default = no value)
Notes
Program the local port number for LCD Control of Voice Mail
Use the same Device Port No. (11) for Network BLF.
Use 10 for Network TPI
Use 12 for Network DSS
Network BLF and DSS are available only with CTX Release 1.3 or higher software
and with CTX WinAdmin Release 1.3 or higher software.
01 Protocol Select communication Protocol.
Possible values: TCP (default) or UDP
Note Select UDP for Network DSS.
02 PC Operation Type Select the Operation Type.
If Server is selected, enter 04 Server Port Number.
If Client is selected, enter the 05 Client IP Address.
Possible values: Server (default) or Client
Note Select Client for TPI.
03 Data Flow Select the data flow protocol for CTX and PC communications.
Note If the logical device set up in 803 SMDR SMDI CTI Port Assignments on
page 4-27 is set to CTI, this field must be set to Asynchronous data flow.
Possible values: Synchronization or Asynchronization (default = Asynchronization)
04 Server Port Number Enter the Server Port Number and proceed to 07 Read Retry Number. This field is
required if Server was selected in 02 PC Operation Type above. If not, leave this field
blank and proceed to 05 Client IP Address.
Possible values: 0~65535 (default = 0)
Note Use 6000 for Network BLF, 3000 for Network DSS and 5000 for Network TPI.
6538