System
I/O Device
4-28 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
Device Port No. Select the Device Port numbers (one port per device).
Possible values: For a RS-232 connection: 1~4 (default = 1)
For an LAN connection: 1~9 (default = 1)
For BLF Networking: 11
For DSS Networking: 12
Notes
• SMDR and SMDI devices can be assigned to any BSIS RS-232 Port.
• BLF and DSS are available only with CTX Release 1.3 or higher software and with
CTX WinAdmin Release 1.3 or higher software.
• LAN devices and PCs can be assigned to logical Ports 1~9 according to the
following logical device number assignments:
LAN Port1 = device 200
LAN Port2 = device 201
LAN Port3 = device 202
LAN Port4 = device 203
LAN Port5 = device 204
LAN Port6 = device205
LAN Port7 = device206
LAN Port8 = device207
Table 4-12 Device Table
Logical
Device
Logical Device
Serial Number
Physical Device Define I/O
Logical
Device
Number
LAN PPP RS-232C
Smart
Media
SMDR 0--OK-100
CTI
0OK---200
1OK---201
2OK---202
3OK---203
4OK---204
5OK---205
6OK---206
7OK---207
8OK---208
SMDI
0OK-OK-300
1OK-OK-301
FIELD DESCRIPTION