Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 9-53
Services
503 Paging Devices Group Assignments
Prerequisite Program: 502 on page 5-23
Assigns BIOU Page Zone Relays to Page Groups.
1. Complete the Paging Device Group
Assignment Record Sheet on page D-54.
2. From the Program Menu, click Services >
External Device > Paging Devices.
3. Enter 00 Zone Relay Number.
4. Check the Paging Groups that you wish to
activate.
5. Select the external generic relay number.
6. Click Submit.
FIELD DESCRIPTION
00 Zone Relay Number Select the BIOU Page Zone relay that should be assigned to the Page Groups
below. This relay activates whenever the selected Page Group is paged.
BIOU1 = Zone Relays 1~4.
BIOU2 = Zone Relays 5~8.
Possible values: 1~8 (default = no value)
01 PG 1~16 PG 16
17 All Page Group
18 All Emergency Page
Group
Check the box if the selected BIOU Page Zone Relay should activate with this
Page Group.
Possible values: On or Off (default)
19 BGM Mute Relay Assign BIOU generic relay as the BGM mute relay. This relay activates
whenever the external page is in use
BIOU1 = Generic Relays 1~4.
BIOU2 = Generic Relays 5~8.
Possible values: 1~8 (default = 0)
Note The CTX100 ACTU built-in relay is programmed as relay 5. For this
relay operation,BIOU2 is installed, as default, in a virtual equipment
position - Cabinet 2, Slot 5, PCB code 20, in Program 100. To install
an actual BIOU2 and disable the ACTU built-in relay, use the
programming telephone to remove the virtual BIOU2 and then install
the actual BIOU2 in Cabinet 01 Slot 01~08 in the normal manner.