EasyManua.ls Logo

Toshiba Strata CTX - BSIS RS-232 Serial Port Setup

Toshiba Strata CTX
533 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System
I/O Device
4-30 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
804 BSIS RS-232 Serial Port Setup
Prerequisite Program: None
Use this screen to setup the RS-232
serial ports on the BSIS PCB.
1. From the Program Menu click
System > I/O Device. The
Equipment Assignment screen
displays.
2. Click the RS232 Serial Port tab. 804
BSIS RS232 Serial Port Set Up
screen displays (shown right).
3. Enter Program 804 data.
4. Click Submit.
05~08 Client IP
Address
Enter the Client LAN IP Address. This field is required if Client was selected in 02 PC
Operation Type above.
Possible values: 0~255 for each octet (default = 0)
Note Enter IP address of Stratagy iES32 or SES.
09 Client Port Number Enter the Client Port number. This field is required if Client was selected in 02 PC
Operation Type above.
Possible values: 0~65535 (default = 0)
10 Read Retry Number Select the Read Retry counter.
Possible values: 0~10 (default = 1)
11 Write Retry Number Select the Write Retry counter.
Possible values: 0~10 (default = 1)
FIELD DESCRIPTION
00 BSIS Port (1~4) Enter the BSIS PCB port number.
Possible values: 1~4 (default = no value)
01 Port Speed Select the data speed for the BSIS port in bits per second (bps).
Possible values: 300, 1200, 2400, 4800, 9600 (default), 19200, 38400 or 57600
Note The total combined maximum speed of BSIS ports cannot exceed 57,600 bps.
02 Port Parity Select the parity error checking method used by the BSIS port.
Possible values: None, Even or Odd (default)
03 Data Bits Select Data Length.
Possible values: 7 Bits (default) or 8 Bits
04 Flow Control This setting indicates the type of flow control used between the BSIS port and the SMDI or
SMDR device. To enable Strata CTX to buffer call records, set this field to Flow.
Possible values: None (default) or Flow
05 Wait Timer Select the maximum time to wait for connection. The Timer value can be one through 255
seconds. Select 0 to set to permanent waiting.
Possible values: 0~255 (default = 30)
FIELD DESCRIPTION