Trunks
300 Trunk Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 6-7
Trunks
01 Line Equipment No. Enter the line equipment number as xxyyzz. Equipment numbers are required
when assigning a new trunk to the system. It can also be used to display the
equipment location of existing trunks.
Example: If the trunk should be connected to an RCOU in cabinet shelf 5, slot
2, circuit 3, enter 050203.
Possible values: xx = Cabinet 01~07; yy = Slot 01~10; zz = Circuit 01~08
...or zz = T1 Circuit 01~24 (CTX670).
xx = Cabinet 01; yy = Slot 01~8; zz = Circuit 01~08
(CTX100) (default = no value).
Cabinet numbers:
CTX100 Select 01 for Base and Expansion cabinet.
CTX670 Select 01 for Base and 02~07 respectively for each Expansion
cabinet.
Slot numbers:
CTX100 Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670 Select 01~08 for Base slots and 01~10 for Expansion slots.
02 Incoming Line Group Assign the trunk to Incoming Line Group. Two-way trunks need to be members
of one incoming and one outgoing line group.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic), 0~128 (CTX670
Exp),
(default = 0)
03 Outgoing Line Group Assign the trunk to Outgoing Line Group. Two-way trunks need to be members
of one incoming and one outgoing line group.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic), 0~128 (CTX670
Exp),
(default = 0)
04 Dial Mode Enter the Dial Mode.
Possible values: DP 10PPS, DP 20PPS or DTMF (default)
DP 10 PPS = Rotary Dial, 10 PPS
DP 20 PPS = Rotary Dial, 20 PPS
05 Signaling Enter the signalling type.
Possible values: DID, Loop (default), Ground, Tie, LP (Japan), SR (Japan) or
ACU (UK)
06 Start Method Enter the Start Method. This setting defines the start protocol method used
between the PSTN and this trunk. For DID/Tie trunks.
Possible values: Immediate Start (default), Timing Start or Wink Start
07 Release Supervision Enable Release Supervision from the CO.
Possible values: Received or Not Received (default)
08 Answer Supervision Enable Answer Supervision from the CO.
Possible values: Received or Not Received (default)
09 Trunk Name Enter the trunk name.
Possible values: Up to 14 ASCII characters (default = no value)