Services
Networking
9-34 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
5. From System > I/O Device, select the LAN Device tab. Refer to Program “801 Network Jack LAN
Device Assignment” on page 4-29. Enter the following values:
• 00 LAN Port No. = 11
• 01 Protocol = TCP
• 02 PC Operation Type = Server
• 03 Data Flow = A Synchronization
• 04 Server Port No. = 6000
• 05~08 Client IP 1-4 No. = Default
• 09 Client Port No. = Default
• 10 Read Retry No. = 1
• 11 Write Retry No. = 1
Note Use the same Device Port No. that was used in Program 803. Example: 11. Enter 6000 in FB04 –
Server Port Number.
6. Make a note of the IP addresses of each networked Strata CTX.
7. Make a note of the Port numbers of each switch.
Note When you start the CTX Attendant Console for the first time, a dialog box appears that requires the
IP addresses and Port numbers of each CTX.
8. From each remote CTX, repeat steps 1~8 to set up Network BLF.
Step 2: From the CTX Attendant Console
1. Click Administration view.
2. Select the BLF Network Control
tab.
3. Enter the IP addresses of local
and remote CTXs.
4. Enter the Port Number.
5. In the Name field, enter the Node
Identified. For example, names
such as Dallas, Chicago, etc.,
depending on where the remote
CTXs are located.
6. Enter the Refresh rate. This is the
frequency that the software will
poll the remote site.
7. Click Add.
8. Enter the Local IP address and IP
addresses of the other sites, then
click OK.
Note When you make the directory in the CTX Attendant Console and when entering user information,
add the Node ID as prefix to the extension.
6599