Maintenance
Components
11-8 Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
Manual Disable/Enable
The components screen enables you to enable or disable any card slot or port.
• When disabled by Disable or Forced Disable, line or stations are made busy and the status will display
“disable by cmd” on the screen. On the telephone LCD, it will display “Make busy.”
• Disable will disable an idle port or slot and cause ports/slots that are in use to go to Pending Disable
– which go to Make Busy after they go idle. Disable waits till a call clears to disable it.
• Forced Disable will disable an idle port or a port that is in-use (the call will be disconnected).
• Enable – removes the Make Busy condition if the slot or port is manually disabled.
Note You cannot enable a slot or port if the system automatically disabled it. The status on the screen will
display “Disabled by Fault.”
Table 11-2 Status Column Error Codes
Component Type Status Code Description
Expansion Cabinet CP Cabinet power failure
Line/Station/Option PCB CR Card PCB set in Program 100, but not installed
Port (ISDN) IL ISDN loss of signal
Port (ISDN) IF ISDN frame sync failure
Port (ISDN) IA ISDN AIS
Port (ISDN-U) UM ISDN-U maintenance mode
Port (ISDN-U) UE ISDN-U Eoc maintenance mode
Port (ISDN-U) UA ISDN-U Act
Port (ISDN-U) UB ISDN-U aib
Port (T1) TY T1 Yellow alarm
Port (T1) TB T1 Blue alarm
Port (T1) TF T1 Frame sync. failure
Port (DKT) DO Digital Telephone not connected.