Telephone Button Programming
200 Series Programs
13-44 Strata CTX Programming - Part 3:Telephone Button Programming 04/03
Example for Setting the data of Single Touch Button from Programming DKT
1. Choose Program 207 and press
+ROG key.
2. Choose Primary DN number and press
+ROG Key.
3. Press
)% and input digits for FB and press +ROG key. In this case 12.
4. Press
)% and Press [9RO8S][)%].
Mic [Vol Up] + [Mic] &MIC
Spkr [Vol Up] + [Spkr] &SPK
Spdial [Vol Up] + [Spdial] &SPD
Redial [Vol Up] + [Redial] &RDL
Cnf/Trn [Vol Up] + [Cnf/Trn] &CNF
Vol Up [Vol Up] + [Vol Up] &UP
Vol Down [Vol Up] + [Vol Down] &DWN
DKT’s FB [Vol Up] + [FB on DKT] &FByy (yy=01-24)
ADM’s FB [Vol Up] + [FB on ADM] &ADxyy (x=1,2 yy=01-20)
DSS’s FB [Vol Up] + [FB on DSS] &DSxyy (x=1-8 yy=01-60)
Note & means ESC code
Programs 208~218
Button Sequence Value(s) Summary
208
Station Timer
Assignments
,
+ROG
Assigns timing parameters to Primary DNS.
208-00 Primary DN
n,
+ROG
n = 1~640 Enter the Primary DN.
Up to 5 digits (default = no value)
208-01 ABR Retry Count
)%
, n,
+ROG
n = 5~20
(default = 15)
Enter the number of retry attempts made by ABR when dialing a busy
telephone number.
208-02 ABR Retry Interval
Timer
)%
, n,
+ROG
n = Up to 5 digits
(default = 60)
Select the amount of time (in seconds) ABR waits between dialing
attempts.
208-03 ABR Recall Timer
)%
, n,
+ROG
n = Up to 9 digits
(default = 20)
Select the number of seconds ABR will call back the station after
receiving ring back tone from the dialed number.
208-04 Hold Recall Timer
)%
, n,
+ROG
n = Up to 5 digits
(default = 60)
Select the number of seconds before a call is placed on hold recalls.
208-05 First Interdigit Timer
)%
, n,
+ROG
n = 0~32
(default = 15)
Select the amount of time a Station has to dial after going off hook
before a call is terminated (ROT is heard).
208-06 Second Interdigit
Timer
)%
, n,
+ROG
n = 0~180
(default = 5)
Select the amount of time the system waits between dialed digits
before terminating a call (ROT is heard).
208-07 Ring Xfer No Answer
Timer
)%
, n,
+ROG
,
+ROG
n = 0~600
(default = 32)
Select the Ring Transfer Idle station or Busy station (Camp-on) Recall
Time (in seconds).
One Touch Data Entry Sequences (continued)
Data for Single Touch Button Setting code from DKT Display Data