EasyManua.ls Logo

Toshiba Strata CTX - Page 356

Toshiba Strata CTX
533 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Telephone Button Programming
500 Series Programs
13-78 Strata CTX Programming - Part 3:Telephone Button Programming 04/03
513-03 B Record for Incoming
Call
)%
, n,
+ROG
n = 1. Enable
2. Disable (default)
Enable B Record generation for incoming calls with or without
incoming SMDR being enabled.
513-04 Abandoned Call
Record Output
)%
, n,
+ROG
n = 1. Enable
2. Disable (default)
Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.
513-05 Display Transferred
Call Records
)%
, n,
+ROG
,
+ROG
n = 1. Source (default)
2. Destination
Select whether to charge a transferred call to the source or
destination party.
514
SMDR for OLG
Assignment

,
+ROG
This command assigns SMDR parameters for OLGs.
514-00 OLG
n,
+ROG
n = 1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
Specify the OLG for which to set SMDR parameters.
514-01 SMDR Record
Display
)%
, n,
+ROG
n = 1. Enable (default)
2. Disable
Enable SMDR Record Display.
514-02 Outgoing Records
)%
, n,
+ROG
,
+ROG
n = 1. Enable (default)
2. Disable
Enable to generate records for outgoing calls. SMDR Record Display
must be on.
514-03 Outgoing Records
)%
, n,
+ROG
,
+ROG
n = 1. Source (default)
2. Destination
Enable to apply the SMDR record of a transferred call to its source or
its destination.
515
View BIOU Control
Relay Assignment

,
+ROG
This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.
Notes
BIOU-1 relays are identified as Control Relays 1~4.
BIOU-2 relays are identified as Control Relays 5~8.
515-00 BIOU (1 or 2)
n,
+ROG
n = 1 or 2 Enter the BOIU PCB number.
Note BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.
515-01 BIOU Relay 1 or 5
)%
, n,
+ROG
n = 1. Not Use (default)
2. Ext Paging
3. Night Bell
4. Night Relay
5. Door Lock
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
NOT USE if the relay is not used.
PAGE MUTE External BGM mute control activates during an
external page (see Program 503 on page 13-73).
NIGHT BELL Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see Program
102 on page 13-12).
NIGHT RELAY Night Mode Control activates continuously
during the system Night Mode (see Program 105 on page
13-18).
DOOR LOCK Door Lock Control activates when a telephone's
Door Unlock button is pressed (see Program 508 on page
13-76).
515-02 BIOU Relay 2 or 6
)%
, n,
+ROG
515-03 BIOU Relay 3 or 7
)%
, n,
+ROG
515-04 BIOU Relay 4 or 8
)%
, n,
+ROG
,
+ROG
Programs 500~577 (continued)
Button Sequence Value(s) Summary

Table of Contents

Other manuals for Toshiba Strata CTX

Related product manuals