EasyManua.ls Logo

Toshiba Strata CTX - Page 71

Toshiba Strata CTX
533 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System
104 System Timer
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03 4-11
System
08 Call Forward No Ans
Time
The System Call Forward No Answer timer specifies the time period that a phone
will ring prior to invoking the Call Forward operation.
Possible values: 1~180 sec. (default = 30)
09 Dial Input Timer This timer permits dial input for a telephone and trunk using DTMF.
Possible values: 0~60 sec. (default = 20)
10 Delay 1 Ringing Timer This timer specifies the time to wait before applying ringing to the designated
phones.
Possible values: 1~60 sec. (default = 12)
11 Delay 2 Ringing Timer Select the time to wait before applying ringing to the designated phones.
Possible values: 1~60 sec. (default = 24)
12 Door Unlock Timer Select the length of time to send an electrical signal to a door for releasing the lock.
Possible values: 1~30 sec. (default = 6)
13 9+11 Judgement Timer The 9+11 Inter-digital timer provides a timing value (1~30 seconds) for the system
to wait for additional digits to be dialed looking for the 911 or 9+911 dialed codes
for treatment using the E911 procedures rather than normal dialing treatment.
Possible values: 1~30 sec. (default = 5)
14 Emergency Call Timer The Emergency Call timer sets a time for advancing the call to the next station in a
list of destinations for the call.
Possible values: 10~180 sec. (default = 30)
15 ABR Busy Detection
Time
The Destination Busy Detection timer sets the time to wait while looking for a busy
condition on an external call. If detected, it will trigger the initiation of the Automatic
Busy Redial cycle.
Possible values: 1~30 sec. (default = 5)
16 Lost Call Timer The Lost Call timer sets the time that a failed transfer recall will ring on the
originating station prior to attempting to recall a secondary location.
Possible values: 1~600 sec. (default = 180)
17 Lost Call Final Timer The Lost Call Final timer sets the time that a failed transfer recall will ring on the
secondary location before being automatically disconnected.
Possible values: 1~600 sec. (default = 30)
18 DTMF Tone Sending
Time
The DTMF tone sending duration for dialing on CO Lines.
Possible values: 80msec (default) or 160msec
19 Auto Disconnect Time after which an unsupervised trunk may be automatically released.
Possible values: 0~60 min. (default = 0)
23 System Timer Network
DSS Refresh Timer
This parameter is available only with CTX Release 1.3 or higher software and with
CTX WinAdmin Release 1.3 or higher software.
Possible values: 20~180 seconds (default = 30)