FM-750 Display User Guide 69
Implement Application Controller 5
Field-IQ master switch box
Note – All systems must have a Field-IQ master switch box.
Feature Function
c Increment/decrement
switch
Increases the applied amount by a set amount (the amount set in the Setup
screen, Rate tab).
d
Rate switch Choose to use preset Rate 1, preset Rate 2, or Manual rate.
e
LED indicator Red – Unit is powered but not communicating with the FM-750 display.
Green – Unit is powered and communicating with the FM-750 display.
Yellow – Unit is initializing communications with the FM-750 display.
f
Automatic/Manual section
switch
Automatic mode – The FmX integrated display automatically opens and
closes sections when entering areas of overlap, non-apply zones, or crossing
boundaries.
Manual mode – The sections are controlled manually, bypassing the FM-750
display.
B
Tip – You can switch from Automatic to Manual mode while
traveling.
g
Master switch A. Jump start (top position)
The sections and rate are ready to be commanded by the FM-750 display,
and the system is overridden to use a preset control speed (the speed is
set in the Setup screen, Override tab).
B
Tip – Use the jump start function if you lose a GPS signal or you want
to start applying before your implement is up to speed.
B. On (middle position)
The sections and rate are ready to be commanded by the FM-750 display.
C. Off (lower position)
Sections are closed and rate is set to zero.