FM-750 Display User Guide 69
Implement Application Controller 5
Field-IQ master switch box
Note – All systems must have a Field-IQ master switch box.
Feature Function
c Increment/decrement
switch
Increases the applied amount by a set amount (the amount set in the Setup
screen, Rate tab).
d
Rate switch Choose to use preset Rate 1, preset Rate 2, or Manual rate.
e
LED indicator Red – Unit is powered but not communicating with the FM-750 display.
Green – Unit is powered and communicating with the FM-750 display.
Yellow – Unit is initializing communications with the FM-750 display.
f
Automatic/Manual section
switch
Automatic mode – The FmX integrated display automatically opens and
closes sections when entering areas of overlap, non-apply zones, or crossing
boundaries.
Manual mode – The sections are controlled manually, bypassing the FM-750
display.
B
Tip – You can switch from Automatic to Manual mode while
traveling.
g
Master switch • A. Jump start (top position)
The sections and rate are ready to be commanded by the FM-750 display,
and the system is overridden to use a preset control speed (the speed is
set in the Setup screen, Override tab).
B
Tip – Use the jump start function if you lose a GPS signal or you want
to start applying before your implement is up to speed.
• B. On (middle position)
The sections and rate are ready to be commanded by the FM-750 display.
• C. Off (lower position)
Sections are closed and rate is set to zero.