EasyManua.ls Logo

WILLETT 430 - Clean Start Jet Sequence

WILLETT 430
207 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Description: Ink System Operation
Issue 2
91
Part No. 306-0430-102
Clean Start Jet Sequence
When the clean start jet sequence is initiated the following automatically takes place:
1
Ink system pressure is set to 4 bar.
2
Wait for 15 seconds to ensure flush pump is full (
Figure 41
).
3
Gutter valve V8 opens.
4
Wait 2 seconds and then valve V7 opens to pressurise the flush pump (
Figure 42
).
5
Wait 3 seconds, then jet valve V11 opens to start jet with pure flush.
6
Run with pure flush for 5 seconds.
7
Ink feed valve V6 opens to allow ink to nozzle (
Figure 43
).
8
Wait 4 seconds while ink and flush are jetted through nozzle.
9
Bleed valve V12 opens.
10
Wait 2 seconds then V7 closes.
11
Wait 10 seconds to bleed nozzle.
12
Bleed valve closes (
Figure 44
).
13
Wait 5 seconds.
14
Modulation and phasing switched on.
15
EHT switched on.
PRE HEAD FILTER
NOZZLE
FILTER
GUTTER
Figure 41 Clean Start Jet Sequence - Fill Flush Pump

Table of Contents