7.3 Program Table Operation
7.3.6 SigmaWin+ Procedures
7-24
• Position/Distance
3.
Click the OK Button.
This concludes the setting procedure.
SPD
Specify the target speeds for positioning.
Select the cells to edit and enter the values directly.
ACC and DEC
Specify the acceleration rates and deceleration rates to use for movement.
1.
Double-click a cell under ACC or DEC.
The Acceleration/Deceleration Dialog Box will be displayed.
2.
Set the acceleration and deceleration rates.
The Same as previous step Check Boxes are selected by default.
To use different values from the previous step, clear the selections of the Same as previous step
Check Boxes and enter the values directly.
Unit Setting Range Default Setting
Reference units -99,999,999 to 99,999,999 STOP
Unit Setting Range Default Setting
Reference units/s 1 to 99,999,999 2,000
Unit Setting Range Default Setting
Reference units/s
2
1 to 99,999,999 :