11.1 List of Parameters
11.1.2 List of Parameters
11-12
PnBA2
2
/STOP
(Program Table
Operation Stop
Input)
Signal Allocation
0000h to
00C3h
− 0020h
After
restart
Setup page 5-10
PnBA3
2
/JOGP
(Forward Jog
Input)
Signal Allocation
0000h to
00C3h
− 0050h
After
restart
Setup page 5-11
PnBA4
2
/JOGN
(Reverse Jog
Input)
Signal Allocation
0000h to
00C3h
− 0060h
After
restart
Setup page 5-11
Continued on next page.
Continued from previous page.
Parameter
No.
Size Name
Setting
Range
Setting
Unit
Default
Setting
When
Enabled
Classi-
fication
Reference
n.X Signal Usage Method
0 Stop program table operation when the /STOP signal turns ON (closes).
1 Stop program table operation when the /STOP signal turns OFF (opens).
2, 3 Program table operation is not stopped.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Signal Usage Method
0 Jog forward while the input signal is ON (closed).
1 Jog forward while the input signal is OFF (open).
2, 3 Forward jog operation is not performed.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Signal Usage Method
0 Jog in reverse while the input signal is ON (closed).
1 Jog in reverse while the input signal is OFF (open).
2, 3 Reverse jog operation is not performed.
n.X Signal Terminal Number
Same as PnBA0 = n.X.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)